Tainan scenario sources
This page is the public citation register for the two Tainan scenarios and facility templates. Each figure is cited beside its value or flagged SELF-DERIVED, ILLUSTRATIVE or SIMULATED with its derivation. The scenario workbooks carry row-level source fields. A source without a public URL is named without an invented link.
Grid, gas and water
- Ministry of Economic Affairs, statutory LNG safety stock: 11 days (2025), 14 days (2027); storage 20 and 24 days.
- Energy Administration, Ministry of Economic Affairs, 2025 Energy Statistics Handbook, table 3-01, Electricity Generation (nationwide, percent). Natural gas share 47.69 percent. https://ea01.moeaea.gov.tw/a0303/02/attachments/handbook/2025/docs/3-01.%E7%99%BC%E9%9B%BB%E9%87%8F%28114%29.xlsx
- Taipower, Hsinta Power Plant unit table and the 14 August 2026 gas procurement notice, for the gas-fired share.
- Taipower, nuclear shutdown statement (17 May 2025). https://hc2.taipower.com.tw/2289/2323/2332/62621/normalPost
- Taipower, nuclear plant status. https://hc2.taipower.com.tw/2764/2826/2842/2844/25134/normalPost
- OpenStreetMap contributors (ODbL), power plants, substations, 345/161/69 kV lines in the Tainan bounding box 120.0 to 120.65 E, 22.85 to 23.45 N; pulled September 2026. https://www.openstreetmap.org/copyright
- NS Energy, Sun Ba II Power Plant, project profile, 30 September 2021: existing Sun Ba plant 980 MW, two 490 MW combined-cycle units (accessed 15 October 2026). OpenStreetMap way 151212447 carries 980 MW (ODbL, September 2026 pull).
- MISO, MTEP24, table 3.1-5, generic 345 kV circuit rating (1,792 MVA), used as a SIMULATED per-circuit basis for the grid ties.
- U.S. Energy Information Administration, Units and Calculators: natural gas heat content 1,036 Btu per cubic foot. https://www.eia.gov/energyexplained/units-and-calculators/
- TSMC, water use at the Southern Taiwan Science Park, 120,000 m³ per day.
- TSMC, UMC and Innolux corporate sustainability reports, electricity and water totals used as SIMULATED shares.
- Reclaimed-water plants and reservoirs serving the park.
Facility templates
- International Energy Agency, Key Questions on Energy and AI (2026): enterprise PUE 1.5 to 1.7; on-site gas overbuild 30 to 70 percent.
- Uptime Institute, Tier III fuel autonomy 12 hours.
- Equinix, 2024 fleet PUE 1.39.
- Google, 2024 fleet PUE 1.09; Microsoft, 2025 WUE 0.27.
- EPRI, 2024, data center campuses of 100 to 1,000 MW; NVIDIA GB200 NVL72 rack density.
- GE Hitachi BWRX-300 and Holtec SMR-300 (300 MWe); NuScale VOYGR module (77 MWe); Westinghouse eVinci (5 MWe).
- IAEA, SMR Platform booklet, SMR operations (commercial SMRs in Russia and China). https://nucleus.iaea.org/sites/smr/Shared%20Documents/SMR_Platform_Booklet_21-10-2024.pdf
- U.S. Energy Information Administration, April 2026, microreactors of 20 MW or less; U.S. Army Janus program; Eielson AFB 1 to 5 MW by 2027.
- Tesla, Megapack 2 XL datasheet (15.6 MWh, 3.9 MW per unit).
- Bloom Energy, Energy Server datasheet, February 2026 (325 kW net AC).
- Hirsch, Parag and Guerrero, Microgrids: a review (2018); MCAS Miramar 21-day islanding.
- SELF-DERIVED: 0.0694 gallons per kWh is the rounded value of 30,000 / (18 x 24 x 1,000). The 30,000 gallons per day and 18 MW are SIMULATED teaching inputs with no outside source.
Connectivity
- SES, O3b mPOWER terminal committed information rate 40 Mbps to 10 Gbps; up to 1.8 Gbps to a land site.
- Chunghwa Telecom, OneWeb license (June 2025), SES O3b mPOWER license (November 2025), gateway memorandum (January 2026).
- Legislative Yuan, satellite-operator foreign-ownership exemption, passed 21 July 2026.
- Ministry of Digital Affairs, 773 non-terrestrial network sites.
- Taiwan Space Agency, LEO demonstration planned for 2027.
- SpaceX, about 2.7 Tbps per V2 Mini launch; OneWeb, about 7 Gbps per satellite, as SIMULATED constellation anchors.
- Ericsson, MINI-LINK E-band, 10 to 25 Gbps at 2 to 3 km.
- Fangshan cable landing and the CHT Tainan IDC.
English display names
A published English name from an operator, builder or park authority, cited in the project's name table; otherwise OpenStreetMap's name:en tag or Latin text in its name tag (ODbL); otherwise SELF-DERIVED: a translation, English already in the scenario data, a composed name or OSM tags. Each record's Name is unchanged.
Basemap tiles
Alidade Smooth, Alidade Smooth Dark and OSM Bright, from tiles.stadiamaps.com: © Stadia Maps © OpenMapTiles © OpenStreetMap contributors. Alidade Satellite, from tiles.stadiamaps.com: © CNES, Distribution Airbus DS, © Airbus DS, © PlanetObserver (Contains Copernicus Data) | © Stadia Maps © OpenMapTiles © OpenStreetMap contributors. OpenStreetMap, from tile.openstreetmap.org: © OpenStreetMap contributors. Cartography only; the overlays drawn on it carry their own flags.
Exercise framing
- Data Center Warfare tabletop exercise concept, Cyber and Innovation Policy Institute, U.S. Naval War College (internal, not linked).
- Lightning AI podcast on training-cluster locality, the origin of the single-site (monolithic) workload rule.
The provenance rule
Every modeled number is tied to a cited source or flagged SELF-DERIVED, ILLUSTRATIVE or SIMULATED. What we cannot measure is stated as a finding.