The analytic core

CIRCUI-T Tool

Model an installation as a network of sources, substations, feeders, stores, and the missions they carry — then break it. Cut a line, lose a generator, take a strike, or run the fuel down, and watch the consequence cascade to the missions that depend on it. The map below loads the scenario named in the address: /circuit/terminal/?scenario=consolidation or ?scenario=fragmentation opens that Tainan layout in Facilitate mode, and the bare address opens CIRCUI-T Tainan - Consolidation in Facilitate mode.

This is the analytic heart of CIRCUI-T: the anticipate-withstand-recover-adapt logic made geographic and quantitative, across eight commodities you can manipulate by hand. Build your own topology or start from a governed scenario, place missions, take a hit, and read the mission state and event ledger in the console on the right. It is deterministic by design and runs from D+0 through D+90: stores deplete, converters stop when their input fuel is unavailable, damage selects a governed repair band with separate lead and active-work time, and every attack or physical assessment lands on a date you can scrub through.

CIRCUI-T 0.1.0-F2j
CIRCUI-T is loading. Keep this tab in front until the map appears.
Tap an element to edit
Local basemap pending
Map data © OpenStreetMap contributors (ODbL): plants, stations, fab sites and most lines. Data centers, service points, workloads and connections: SIMULATED. English names: SELF-DERIVED unless cited.
Missions
No missions yet. Use + New Mission to add missions to a site.
Event Log
AWAITING INPUT

1 · Load or import a scenario, then place sources / substations.
2 · Draw lines toward a site (above or below ground).
3 · Add missions with + New Mission and set the supplies they need.
4 · Left-click any node or line to set power, damage, and properties — the cascade prints here.

What this is and isn't. Transmission line geometry in the Tainan scenarios comes from OpenStreetMap (ODbL); the completion feeders that join stations the mapping leaves unconnected are SIMULATED. None of it is surveyed or assessed grid data. Infrastructure sources and scenario assumptions are listed on the Sources page; row-level citations and provenance flags travel with scenario exports. This is a teaching model for how dependencies cascade, not a representation of any installation's real vulnerabilities. The same standard the rest of this site follows: the rule we follow.

What this build does

The terminal models a compute cluster's infrastructure as a multi-commodity network and is deterministic by design. Its Dependency Analysis tool compares modeled consequences without turning the model into a predictor or optimizer. This build implements:

  • A multi-commodity cascade engine: deterministic max-flow across electric, water, natural gas, steam, oil, fuel, data and compute, with Military reserve, Critical civil and Commercial tiers allocated in priority order and per-dependency critical or degrading handling.
  • Compute as a commodity: data centers are converters with electric, water and data inputs, IT-MW output, PUE and WUE fields, a cooling-mode preset and a scenario-wide PUE multiplier. Compute reaches workloads over modeled compute links.
  • A military reserve: each data center sets aside a percentage of its compute for Military reserve workloads; single-site workloads are placed whole or reported short.
  • Stored gas: when a scenario enables it, gas plants draw from explicit inventories that refill over named import lanes from external sources; the Tainan scenarios model Yong-An and a national stock this way.
  • Seventeen facility templates with provenance on the card: five data center classes, SMRs and microreactors, a grid battery block, a fuel cell class, a self-powered campus, a microgrid composite with a PCC switch, and connectivity objects (constellation, space gateway, satellite terminal, wireless backhaul).
  • Two Tainan layouts, Consolidation and Fragmentation, embedded from reviewed workbooks with a Sun Ba II toggle, twelve plays, and a scenario ledger of every SIMULATED connection.
  • Governed tools: governed kinetic and cyber effects with tri-state cyber assessment, damage and hardening rules, physical assessments, the 90-day event-sourced timeline, governed repair episodes, the scenario workbook (now v18 with guarded readers back to v10), read-only Dependency Analysis, governed catalogs and the DATA editor.

Flow versus stored, and what is SIMULATED. Electric, water, steam, data and compute are flows. Oil and fuel are stored reserves, and gas is stored when the scenario says so. In the Tainan scenarios the LNG inventories are SELF-DERIVED from the statutory stock rule and the modeled consumers' burn; generator fuel stocks are SELF-DERIVED from template hours; every data center, its capacity and its placement is SIMULATED. Time-to-GOOD assumes the current repair plan holds unchanged.

Deferred to v1.1

Listed so the gap between what the terminal does today and where it is going stays explicit:

  • Dispatch-aware fuel draw, so backup generators burn only for the output they deliver, and battery dispatch, so storage can ride through an islanding window.
  • A first-class interdiction event that zeroes resupply for a period with a step restoration.
  • Gateways and towers as electric loads, so communications failure follows grid failure.
  • Automatic islanding on upstream loss rather than a user-set day range.
  • Process gas at fabs, and a fab restart clock.
  • Scenario persistence beyond the browser's local storage quota.
  • A direct-to-device throughput lever.

These are planning candidates, not commitments.